IEC 61851-1 Clause 12.9 High Low Temperature Climate Chamber

Brand Name : Sinuo

Model Number : SN886

Certification : Calibration Certificate (Cost Additional)

Place of Origin : China

MOQ : 1

Price : Customized

Payment Terms : L/C, T/T, Western Union, MoneyGram

Supply Ability : 5 Sets Per Month

Delivery Time : 1 Month

Packaging Details : Plywood

Applied Standard : IEC 61851-1 and etc.

Applied Clause : Clause 12.9 and 12.10

Temperature Deviation : ≦±2.0℃

Temperature Fluctuation : ±0.5℃

Temperature Uniformity : ±2℃

Humidity Range : 30%〜98%RH

Warranty : 1 year

Control And Operation : PLC, Touch Screen

Contact Now

IEC 61851-1 Clause 12.9 High & Low Temperature Climate Chamber

Applied standards:
This programmable temperature chamber is required by:

IEC 61851-1 clause 12.9 and 12.10, IEC 61851-23 clause 101.2.1.1

IEC60068-2-1:2007 “Environmental Testing-Part 2-1: Tests-Test A: Cold, IDT”

IEC60068-2-2:2007 “Environmental Testing-Part 2-1: Tests- Test B-Dry heat, IDT”

IEC60068-2-78:2012 “Environmental Testing-Part 2-78: Tests-Test Cab: Damp heat, steady state, IDT”

IEC60068-2-30:2005 “Environmental Testing-Part 2-30: Tests-Test Db: Damp heat, cyclic (12h+12h cycle) , IDT”

Main Technical parameters:
Samples and Restrictions Electrical, electronic, mechanical and large parts, semi-finished products, finished products, etc.
Application It is used for high and low temperature and damp heat tests on electricians, electronics, machinery, and large parts, semi-finished products, and finished products. Process quality and reliability testing of products, parts, etc. under simulated temperature and humidity conditions.
Test Principle The heating, humidification and refrigeration system is used to control and change the ambient temperature and humidity in the chamber, simulating the ambient temperature / humidity and alternating procedures required by the testing.
Structure Adopts closed chamber structure
Use Environment

Power supply: AC380V±5%/50Hz (R, S, T, N phase plus ground wire) (voltage fluctuation ≦ ±10%), grounding resistance ≦ 4Ω

Ambient temperature: 5 °C ~ +35 °C, relative humidity: ≦85% RH should not have high concentration of dust, corrosive gas, flammable and explosive objects

Control & Operation PLC and touch screen intelligent control system
Chamber Size (Optional)

8m3: WDH=2×2×2m

12m3: WDH=3×2×2m

20m3: WDH=2×2×5m

50m3: WDH=5×2×5m

Temperature Range (Optional)

Maximum test temperature: 80 ° C, 120 ° C;

Minimum test temperature: -60 ° C, -40 ° C, -20 ° C, 0 ° C

Temperature Deviation ≦±2.0℃
Temperature Fluctuation ±0.5℃
Temperature Uniformity ±2℃
Humidity Range 30%〜98%RH
Humidity Deviation ±5.0%RH
Heating Rate ≤2.5°C/min (nonlinear, no load)
Cooling Rate Average 1.0 ° C / min
Temperature and Humidity Range Icon
Main Components of Refrigeration system:

Features:
1. The test system has advanced and reasonable structural design, standardized manufacturing process, beautiful appearance and generous appearance.
2. The main functional components of the test chamber are world famous branded ones. The test chamber has best control of noise and energy saving.
3. The matching of components and assembly is good. The main functional components are imported from the internationally branded companies, which improves the safety and reliability of the test chamber, and can ensure the long-term, high-frequency usage purposes.
4. The equipment has good operability, maintainability, good temperature stability and durability, good safety performance. It does not pollute the environment and endanger human health.


Product Tags:

IEC 61851-1 Low Temperature Climate Chamber

      

Clause 12.9 Low Temperature Climate Chamber

      

PLC Vehicle Testing Equipment

      
Wholesale IEC 61851-1 Clause 12.9 High Low Temperature Climate Chamber from china suppliers

IEC 61851-1 Clause 12.9 High Low Temperature Climate Chamber Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Sinuo Testing Equipment Co. , Limited
*Subject:
*Message:
Characters Remaining: (0/3000)